Digital multimeter with both automatic and manual measuring range adjustment. Analogue bar graph for quick or unstable signals. True RMS for both voltage and current when measuring non-linear signals. Records maximum and minimum value. Measures direct/alternating voltage, AC/DC, resistance, capacitance, frequency/ diode and temperature. Beside, continuity test with buzzer, hold function, display lighting, low battery capacity warning. Supplied complete with test leads, USB cable for data transfer to PC, K-K-type thermocouple and adapter for temperature measurment & batteries. Scale length 6000. Insulation CAT III 1000 V/ CAT IV 600 V according to IEC 61010. Fuse protected to 11 A.
Safety classification CAT III 1000 V, CAT IV 600 V
Common Characteristics
Operating temperature max./min.40/0 °C
Voltage measurement range (AC) max./min. 1000 V/60 mV
Voltage accuracy/resolution (AC) ± (1.2%+5)/0.01 mV
Voltage measurement range (DC) max./min. 1000 V/60 mV
Voltage accuracy/resolution (DC) ± (0.8%+5)/0.01 mV
Current measurement range (AC), max./min. 20 A/600 µA
Current accuracy/resolution (AC) ±(1.2% +5)/0.1 µA
Current measurement range (DC), max./min. 20 A/600 µA
Current accuracy/resolution (DC) ±(1% +2)/0.1 µA
Resistance measurement range, max./min. 60 M?/600 ?
Resistance accuracy/resolution ± (1.2%+2) - ± (2.0%+5)/0.1 ?
Frequency measurement range, max./min. 10 MHz/10 Hz
Frequency accuracy/resolution ± (0.1% + 4)/0.01 Hz-0.01 MHz Hz
Capacitance measurement range, max./min. 60 mF/0 nF
Capacitance accuracy/resolution ± (3%+5)/0.01 nF
Temperature measurement range, max./min. 1000 °C-40 °C
Temperature accuracy/resolution ± (1.0% + 3 °C)/0.1 °C-1 °C, 0.2 °F-2 °F
Weight 0.36 kg